2958 Integrated Delayed Egress Lock
Hager
• Voice and digital display provides informative annunciation for people without prior knowledge, including the blind and hearing impaired
• Field selectable voice & tone or tone only
• Voice provides warning or safety message, countdown and time of door release
• Digital countdown display also indicates if door was open after lock release.
• Fixed 15 second delay or selectable 15 or 30 second exit delay
APP LICAT ION
Airport & Public Facility Security & Safety
Control pedestrian traffic in government, public facilities and transportation facilities, including airport jetways and tarmacs.
Loss Prevention
Provide theft protection of merchandise, technology and other valuables such as, art and museum artifacts.
Wandering Patient and Infant Protection
Restrict the egress of psychiatric and drug rehab patients, elderly patients in assisted living facilities and restrict the movement of nursery infants for their own safety and security.
Operation
Typically used on exit doors, when unauthorized egress is initiated when in the locked mode. 2958 delays egress through the door for 15 or 30 seconds. Meanwhile, the person exiting must wait while personnel or security respond. The door unlocks after 15 seconds have elapsed, permitting egress. A signal from the fire life safety system will release the lock for uninhibited egress in an emergency. 30 second delay available where approved.
FACILITY APPLICATION
• Airports
• Convention Halls
• Wholesale Stores
• Retail Stores
• Long Term Care
• Drug Rehab
• Psychiatric Care
• Infant Nurseries
• Museums
• Art Galleries
• Warehouses
• Technology Facility
CODE COMPLIANCE
• IBC, International Building Code - 1008.1.8.6 Delayed Egress Locks
• IFC, International Fire Code - 1008.1.8.6 Delayed Egress Locks
• NFPA 101, Life Safety Code - 7.2.1.6.1 Delayed Egress Lock
• CBC, California Building Code - 1008.1.8.6 Special Egress Control Devices
• BOCA, National Building Code - 1017.4.1.2 Special Locking Arrangements
• Chicago Building Code - 10 (13-160-269) Electro-Magnetic Locking Devices. Certificate of approval available
ACCESS CONTROL
Access controls may be utilized for authorized egress, access and lock reset. Access from the exterior of latching doors
requires an additional means of mechanical lock release, such as a mechanical key or electric strike.
LOCAL APPROVAL
All installations must be approved by the Authority Having Jurisdiction (AHJ).
SINGLE MODEL
For use with single doors equipped with mortise or Rim mount exit devices, Surface or Concealed Vertical Rod exit devices with surface or concealed strikes and triggers, or mortise or cylinder locksets.
TANDEM MODEL
• Activating either door unlocks both doors
• For use with pairs of doors equipped with mortise or rim mount exit devices, surface or concealed vertical rod exit
devices with surface or concealed strikes and triggers, or mortise or cylindrical locksets
VERBAL AND DIGITAL ANNUNCIATION
Incorporates an alternating verbal message, verbal countdown and alarm tone, plus a large digital count- down display and door release indicator that provides a clear warning for the safety of people without prior knowledge of door operation, including the blind and hearing impaired.
FEATURES
• Field selectable voice message and alarm tone, or alarm tone only, 75 db @ 3 ft
• The visual display provides a digital countdown, indicates lock release and verifies if the door was opened for egress.
• Choice of fixed 15 second exit and 1 second nuisance delay or field selectable 15 or 30 second exit delay and 1 or 2 second nuisance delay
• Field selectable security or safety message
• Field selectable activation: Door movement Exit device with switch kit Exit sense bar for non-latching doors
• Field selectable automatic or manual relock upon power up after emergency release or power loss.
• Integrated 3 position key switch provides: Lock and alarm reset Manual power-up Sustained bypass, timed bypass,
adj. for 1, 15, 20 or 30 seconds
• Field selectable door prop alarm: Alarm sounds when door is left open after selected bypass time has elapsed.
• Anti-tailgate feature
• Single or multi-door zone control and reset capability Control Inputs
• Remote access control and REX input, field adjustable for 1,15, 20 or 30 seconds
• Remote reset input
• Manual power-up input
• Emergency release input
• Anti-tailgate input
Monitoring Outputs
• Door secure and unlocked output
• Delayed egress activation alarm output
OPTIONS
• Custom message, language or shortened exit delay times
• Magnetic Bond Sensor output
• Door Status Sensor output
• Anti-tamper sensor output
SELF ADJUSTING DOO R MOVEMENT SEN SOR
The built-in door movement sensor may only be used with doors equipped with a latch assembly, such as a mechanical
lockset or exit device. The mechanical latch mechanism must be locked on the exterior and unlocked on the interior. From the inside, retracting the door latch and applying pressure causes limited door movement. The built-in activation trigger senses the door movement and initiates delayed egress operation. The self adjusting sensor helps prevent false triggering.
EXTERNAL DEVICE TRIGGER INPUT
Activation For Non-Latching Doors
The external activation trigger input must be used with doors without latch assemblies, such as latchless glass and herculite doors. Activation may be triggered by the 4801 switch bar or request-to-exit push bar. A power transfer device is required. Pushing on the request to exit push bar immediately activates the delayed egress operation.
Activation For Latching Doors
Where preferred, activation may be accomplished by a latch monitoring strike, or a switch installed in a standard latching
exit device or lockset. A power transfer device is required for exit devices equipped with a trigger switch.
AUTO MAT IC OR MANUA L PO WER UP
Field selectable method of lock power-up, automatic or manual, after power loss or emergency release.
Auto Power-Up
When selected, regardless of the means of deactivation, relocking occurs when power is restored and/or the fire life safety panel is reset. Manual Power-Up UBC, California Building Code (OSHPD) Compliant Reset When selected, regardless of the means of deactivation, relocking is by manual means only at the door. Only after power restoration
and/or fire life safety panel reset, the door may be relocked by actuating the standard built-in key reset or optional wall
mounted key switch, push switch or digital keypad located adjacent to the door.
ELECTRICAL SPE CIFICAT ION S
Input: Dual voltage sensing
Voltage: 12/24 VDC +/- 10%
Standard 1650 lbs holding force
2958 830mA @ 12VDC
450mA @ 24VDC
2958T 1500mA @ 12VDC
850mA @ 24VDC
Inputs
Request to Exit - Normally open, dry
Fire Alarm Release - Alarm panel closed dry contact. Opening of contact releases lock
Monitoring Outputs
Alarm Output:
SPDT Dry, 1 Amp @ 30VDC
Lock Secure Unlocked Output:
SPDT Dry, 1 Amp @ 30VDC
DPS Door Position Status: (optional)
SPDT Dry, 250 mA @ 30VDC
BAS Magnetic Bond Status: (optional)
SPDT Dry, 250 mA @ 30VDC
ATS Anti Tamper Sensor: (optional)
SPDT Dry, 1 Amp @ 30VDC
MECHANICAL SPECIFICATIONS
BHMA Certified ANSI Grade 1
Holding Force: 1650 lbs (2958)
Single: 11”L x 2-3/4”H x 2-5/8”D (279 x 70 x 67mm)
Tandem Master: 11”L x 2-3/4”H x 2-5/8”D (279 x 70 x 67mm)
Slave: 11”L x 2-3/4”H x 2-5/8”D (279 x 70 x 67mm)
Armature: 7-3/8”L x 2-3/8”H x 9/16”D (187 x 60 x 14mm)
MODELS
2958 Single
2958T Tandem
OPERAT ION MODE
NA NFPA 101, IBC and IFC Compliant
Field selectable:
15 or 30 second exit delay
1 or 2 second nuisance delay
Field selectable automatic or manual power-up after emergency release
ND California Building Code (OSHPD ), NFPA 101, IBC & IFC Compliant
• Fixed 15 second exit delay
• Fixed 1 second nuisance delay
• Field selectable automatic or manual power-up after power loss or emergency release
BD BOCA, National Building Code
Chicago Building Code
• 15 second fixed exit delay
• 1 second nuisance delay
• Auto reset 30 seconds after door closure - auto reset is retriggered if door opens before 30 seconds has elapsed
• 45 seconds when AHJ approved
BUILT-IN RESET AN D CONT ROL
KS Built in key switch. Provides 1-30 second timed bypass, sustained by- pass and alarm reset (standard)
PS Built in reset push switch. Available with NFPA (NA) only
NS Less key or push switch
FINISHE S
Anodized Finishes
ALM 628 Aluminum (standard)
DBZ 313 Dark Bronze
BLK 335 Black
Special Plated Finishes
US3 605 Bright Brass
US4 606 Dull Brass
US26 625 Bright Chrome
US260 626 Dull Chrome
OPT ION S
DPS (Door Position Status): Provides remote monitoring of the door open or closed status and indicates the door has actually been opened for egress after alarm activation. (Specify 2 for tandem)
MBS (Magnetic Bond Alert Sensor): Indicates locked with full holding power or unlocked, reduced holding power, tampering or foreign material between the electromagnet and armature. (Specify 2 for tandem)
ATS (Anti-Tamper Switch): Detects attempt to remove the access cover. (Specify 2 for tandem)